THE DENTAL AWARDS 2025 – REGISTER NOW!

The benefits of a vacuum sterilizer

Featured Products Promotional Features

  Posted by: Dental Design      6th October 2020

Let’s hope that life after lockdown may present opportunities for positive change, even within the dental care setting. It is well recognised that for the most part, infection control processes in dental practices are well implemented.  Considering the COVID-19 pandemic, now is the time for you to re-evaluate your practice processes so that you may improve the quality of treatment provided. This is vital considering many patients will want reassurance that dental professionals are taking the necessary precautions to reduce the risk of disease transmission in practice. The importance of being proactive in terms of infection prevention and control cannot be underestimated. As such, dentists should seek to further optimise decontamination protocols, particularly with regard to sterilization.

Sterilization is an essential step in the reprocessing of dental instruments – including those with hollow bodies (e.g. handpieces) – that have become or are potentially contaminated with saliva, blood, or other bodily fluids. The aim of sterilization is to break the chain of potential cross-infection between patients by killing microorganisms that may be present on the surface of dental instruments, including spores. The sterilization process must be validated to ensure that instruments are reliably and consistently sterilized using predetermined and reproducible conditions.[i]

Of all those available, sterilizers that deliver saturated steam under pressure are recommended as the safest, most efficient method of sterilizing instruments. Steam sterilization involves heating water within a closed chamber, resulting in the production of steam. This drives air from the chamber out of an escape valve that closes, enabling pressure to build over time. The basic principle of steam sterilization is to expose instruments to direct steam contact at the required temperature and pressure for a specific holding time.[ii]

As they are non-toxic, cost-effective, and rapidly microbicidal and sporicidal, steam sterilizers are widely used across dental practices. Furthermore, clinicians have the choice between three types of steam sterilizers: N, B and S. While each of these autoclaves boast their own advantages, type B sterilizers – otherwise known as vacuum sterilizers – are the first-choice system for many clinicians, as they offer the widest range of applications.

Type B sterilizers are designed with a pump that creates a vacuum to ensure air is fully removed before steam enters the sterilizing chamber. The benefit of this vacuum function is that there is almost instantaneous and complete steam penetration ­– even in the case of porous materials or hollow items – resulting in faster and more thorough sterilization of the entire load.[iii] As well as offering the capability to produce sterile wrapped instruments, type B autoclaves overcome the issue of wet instrument packs with a post-cycle vacuum that removes steam and facilitates fast drying once sterilization is complete.

Another benefit of vacuum sterilizers is that they can quickly heat and penetrate textiles, making them ideal for sterilizing personal protective equipment (PPE). Moreover, these autoclaves can be used for the sterilization of lumened instruments as specified by the manufacturer. Given that they can accommodate a wide variety of load types quickly and effectively ­­– including handpieces – it’s no wonder that vacuum sterilizers are a must-have piece of equipment for dental practices.

Of course, choosing the most suitable autoclave can be a challenge with such a vast range of options available on the market. Investing in the right solution for you and your dental team begins with considering factors such as the autoclave’s chamber size and cycle duration. The bigger the chamber, the greater the capacity for instruments, although a smaller chamber typically equates to faster overall cycle times. The faster the cycle, the quicker the turnaround of instruments for a more streamlined workflow. Ultimately, your sterilizer should offer the most appropriate choice of cycles to meet your sterilization requirements.

Investing in robust and reliable dental equipment can make all the difference to improving standards and optimising decontamination procedures within your practice. Ideally, clinicians should select proven solutions that support their day-to-day infection control protocols, and enable them to effectively minimise the risk of cross-infection. Leading manufacturer, W&H, offers a range of top-quality autoclaves, including the Lara type B vacuum sterilizer with Eco Dry technology, which can process a typical 2kg cycle load in 38 minutes. The Lara affords the benefits of economic water consumption and unique upgradeability options for future and individual demands. The new generation Lisa type B vacuum sterilizer from W&H – boasting a reputation for unrivalled reliability and efficiency – offers intuitive connectivity and a comprehensive traceability system with real-time remote monitoring. The innovative Lisa sterilizer features patented Eco Dry+ technology that reduces the cycle times to as little as 28 minutes or a rapid 13 minute ‘S’ class cycle, thereby optimising energy consumption for cost-effective sterilization with each load. 

Dental professionals are on the front line of the war against infectious diseases. The COVID-19 pandemic has demonstrated the exact cost of failing to take the required steps to prevent the spread of infection. The equipment you use to clean and sterilize your instruments is crucial to delivering the safest, most effective dental treatment. As such, it is important that you are prepared to further optimise your decontamination workflow, and invest in trusted solutions that can better aid in protecting yourself, your team, and your patients from potentially harmful pathogens. 

 

To find out more visit www.wh.com/en_uk, call 01727 874990 or email office.uk@wh.com

 

 

[i] Laneve, E., Raddato, B., Dioguardi, M., Di Gioia, G., Troiano, G. and Lo Muzio, L. (2019) Sterilisation in Dentistry: A Review of the Literature. International Journal of Dentistry. 6507286. DOI: 10.1155/2019/6507286. Link: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6350571/. [Last accessed: 11.06.20].

[ii] Scottish Dental Clinical Effectiveness Programme. (2011) Sterilization of Dental Instruments: Dental Clinical Guidance. Link: http://www.sdcep.org.uk/wp-content/uploads/2015/01/SDCEP+Sterilization+of+Dental+Instruments.pdf. [Last accessed: 11.06.20].

[iii] Centers for Disease Control and Prevention. (2016) Steam Sterilization. Link: https://www.cdc.gov/infectioncontrol/guidelines/disinfection/sterilization/steam.html. [Last accessed: 11.06.20].


Join our
Mailing List

Sign up to our newsletter and keep up to date on the latest happenings in the dental market.

Sign up today